300W Single
Model Number |
Output |
Tol |
RCN |
Effi |
S-300-5 |
5V,0~45.0A |
± 2% |
150mV |
73% |
S-300-12 |
12V,0-25.0A |
± 1% |
200mV |
82% |
S-300-13.5 |
13.5V,0〜22.0A |
± 1% |
200mV |
82% |
S-300-24 |
24V,0~12.5A |
± 1% |
200mV |
84% |
S-300-27 |
27V,0-11.0A |
± 1% |
200mV |
84% |
S-300-48 |
48V,0-6.5A |
± 1% |
240mV |
86% |
AC input voltage range
|
85~132VAC/176~264VAC selected by switch 47~63Hz,248~370VDC
|
Input current
|
6.5A/115V 4A/230V
|
AC Inrush current
|
Cold-start current 25A/115V 50A/230V
|
Leakage current
|
<3.5mA/240VAC
|
Overload protection
|
105%-150% Type: pulsing hiccup shutdown Reset: auto recovery
|
Over-voltage protection
|
5.75~6.75V
|
9.4~10.9V
|
13.8~16.2V
|
15.5~18.2V
|
18~21V
|
27.6~32.4V
|
33.7~39.2V
|
57.6~67.2V
|
Temperature coefficient
|
±0.03%/°C(0~50°C)
|
Setup, rise, hold up time
|
200ms, 100ms, 20ms
|
Vibration
|
10~500Hz, 2G 10min,/1 cycle. Period for 60min,Each axes
|
Withstand voltage
|
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
Isolation resistance
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
|
Working temperature and humidity
|
-10°C~+60°C(Refer to output load derating curve),20%~90%RH
|
Store temperature and humidity
|
-20°C~+85°C,10%~95%RH
|
Overall dimension
|
215X115X50mm (L*W*H)
|
Weight
|
1.15kgS
|
Safety standards
|
Design refer to UL1950
|
EMC standards
|
Design refer to FCC part 15J class A
|
Note
|
1. The parameter under the testing condition : 230vAC input ,rated load,25°C70% RH. Temperature.
2. Tolerance the setting tolerance, circuit stability and load stability.(Note:5).
3. Wave test: adopting "A12"double wire for 20MHz, and 0.1 UF&47UF capacitor short-circuit for interrupting.
4. Inlet voltage stability test : the lowest voltage will be up to the highest voltage when the circuit overload.
5. Load stability test: The load is from 0% to 100%.
|
Dimension
|