150W Single
Model Number |
Output |
Tol |
RCN |
Effi |
S-150-5 |
5V,0~30A |
± 2% |
150mV |
78% |
S-150-7.5 |
7.5V,0~20.0A |
± 1% |
150mV |
80% |
S-150-9 |
9V,0~16.7A |
± 1% |
180mV |
80% |
S-150-12 |
12V,0~12.5A |
± 1% |
180mV |
82% |
S-150-15 |
15V,0~10.0A |
± 1% |
180mV |
84% |
S-150-24 |
24V,0~6.5A |
± 1% |
240mV |
85% |
S-150-48 |
48V,0~3.2A |
± 1% |
240mV |
87% |
S-150-13.5 |
13.5V,◦〜11.2A |
± 1% |
180mV |
83% |
S-150-27 |
27V,0~5.6A |
± 1% |
240mV |
86% |
AC input voltage range
|
85~132VAC/176~264VAC selected by switch 47~63Hz,248~370VDC
|
Input current
|
3.2A/115V 1.6A/230V
|
AC Inrush current
|
Cold-start current 30A/115V 60A/230V
|
Leakage current
|
<3.5mA/240VAC
|
Overload protection
|
105 ~ 150% Protection type :pulsing hiccup shutdown Reset: auto recovery.
|
Over-voltage protection
|
115%~135% Protection type :shut off output
|
Temperature coefficient
|
±0.03%/°C(0~50°C)
|
Setup, rise, hold up time
|
100ms, 50ms, 20ms
|
Vibration
|
10~500Hz, 2G 10min,/1 cycle. Period for 60min,Each axes
|
Withstand voltage
|
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
Isolation resistance
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
|
Working temperature and humidity
|
-10°C~+60°C(Refer to output load derating curve),20%~90%RH
|
Overall dimension
|
199X98X38mm (L*W*H)
|
Weight
|
0.7kgS
|
Safety standards
|
UL 1950 TUV EN60950 Approved
|
EMC standards
|
CISPR22(EN 5022),IEC1000-4-2,3,4 IEC1000-3-2 Verification
|
Note
|
1. The parameter under the testing condition : 230vAC input ,rated load,25°C70% RH. Temperature.
2. Tolerance the setting tolerance, circuit stability and load stability.(Note:5).
3. Wave test: adopting "A12"double wire for 20MHz, and 0.1 UF&47UF capacitor short-circuit for interrupting.
4. Inlet voltage stability test : the lowest voltage will be up to the highest voltage when the circuit overload.
5. Load stability test: The load is from 0% to 100%.
|
OVERALL DIMENSION(Unit:mm)
|