MODEL |
S-50-5 |
S-50-12 |
S-50-15 |
S-50-24 |
DC VOLTAGE |
5V |
12V |
15V |
24V |
RATED CURRENT |
10A |
4.2A |
3.4A |
2.1A |
CURRENT RANGE |
0 ~ 10A |
0 ~ 4.2A |
0 ~ 3.4A |
0 ~ 2.1A |
RATED POWER |
50W |
50.4W |
51W |
50.4W |
RIPPLE & NOISE (max.) Note.2 |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
VOLTAGE ADJ. RANGE |
4.75 ~ 5.5V |
10.8 ~ 13.2V |
13.5 ~ 16.5V |
22.6 ~ 26.4V |
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
LOAD REGULATION |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
SETUP, RISE, HOLD TIME |
200ms, 100ms, 20ms at full load |
VOLTAGE RANGE |
85 ~ 132VAC / 170 ~ 264VAC selected by switch 240 ~ 370VDC |
FREQUENCY RANGE |
47 ~ 63Hz |
EFFICIENCY (Typ.) |
71% |
78% |
78% |
82% |
AC CURRENT |
1.3A/115VAC 0.65A/230VAC |
INRUSH CURRENT (max.) |
COLD START 18A/115VAC 36A/230VAC |
LEAKAGE CURRENT |
<1mA / 240VAC |
OVERLOAD |
105 ~ 150% rated output power |
Protection type : Fold back current limiting, recovers automatically after fault condition is removed. |
WORKING TEMP. |
-10 ~ +60ºC (Refer to output load derating curve) |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-20 ~ +85ºC, 10 ~ 95% RH |
TEMP. COEFFICIENT |
±0.03%/ºC (0 ~ 50ºC) |
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY STANDARDS |
Design refer to UL1012 |
WITHSTAND VOLTAGE |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI CONDUCTION & RADIATION |
Design refer to FCC Part15 J Conduction Class B |
MTBF |
408.3K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION |
159*97*38mm (L*W*H) |
PACKING |
0.444Kg; 30pcs/14.92Kg/0.0250CMB |
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation. |