Model |
S-25-5 |
S-25-12 |
S-25-15 |
S-25-24 |
Output |
DC Voltage |
5V |
12V |
15V |
24V |
Rated Current |
5A |
2.1A |
1.7A |
1.1A |
Current Range |
0~5A |
0~2.1A |
0~1.7A |
0~1.1A |
Rated Power |
25W |
25.2W |
25.5W |
26.4W |
Ripple & Noise (max.) Note.2 |
50mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Voltage Adj. Range |
4.75~5.5V |
10.8~13.2V |
13.5~16.5V |
21.6~26.4V |
Voltage Tolerance Note.3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
Setup,Rise, Hold time |
300ms, 50ms, 80ms/230VAC 800ms, 50ms, 10ms/115VAC at full load |
Input |
Voltage Range |
85 ~ 132VAC / 170 ~ 264VAC selected by switch 240 ~ 370VDC |
Frequency Range |
47~63HZ |
Efficiency(Typ.) |
72%/115VAC |
76%/115VAC |
77%/115VAC |
80%/115VAC |
AC Current |
0.6A/115VAC 0.35A/230VAC |
Inrush Current (max.) |
COLD START 15A/115VAC 30A/230VAC |
Leakage Current |
<0.75mA / 240VAC |
Protection |
Over Load |
110~115% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed. |
Over Voltage |
5.75V~6.75V |
13.8V~16.2V |
17.25V~20.25V |
27.6V~32.4V |
Protection type : Hiccup mode, recovers automatically after fault condition is removed. |
Environment |
Working Temperature |
-10 ~ +60°c (Refer to output load derating curve) |
Working Humidity |
20~90% RH Non-condensing |
Storage temp.& humidity |
-20~+85°C, 10~95%RH |
Temp. coefficient |
±0.03%/°C (0~50°C) |
Vibration |
10 ~ 500Hz, 2G 10min./1 cycle,60min.each along X,Y,Z axes |
Safety & EMC
(Note 4.)
|
Safety Standards |
UL1012, TUV EN60950-1 Approved |
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI Conduction & Radiation |
Compliance to EN55022 (CISPR22) Class B |
Harmonic Current |
Compliance to EN61000-3-2,-3 |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5; ENV50204, EN55024, Light industry level, criteria A |
Others |
MTBF |
330.8K hrs min. MIL-HDBK-217F (25°c ) |
Dimension |
99*97*36mm (L*W*H) |
Packing |
0.39Kg; 45pcs/18Kg/0.9CUFT |
Note |
1. All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25°C of ambient temperature. |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 10uf parallel capacitor. |
3. Tolerance: includes set up tolerance, line regulation and load regulation. |
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |