Model
Specification
|
S-500-5 |
S-500-12 |
S-500-15 |
S-500-24 |
S-500-48 |
DC Output voltage |
5V |
12V |
15V |
24V |
48V |
Output voltage range(Note:2) |
±2% |
±1% |
±1% |
±1% |
±1% |
Rated output current |
80A |
40A |
32A |
20A |
10.4A |
Output current range |
0~80A |
0~40A |
0~32A |
0~20A |
0~10.4A |
Wave and noise(Note:3) |
75mVp-p |
120mVp-p |
150mVp-p |
240mVp-p |
240mVp-p |
Inlet stability(Note:4) |
0.5% |
±1% |
±1% |
±1% |
±1% |
Load stability(Note:5) |
±3% |
±1% |
±1% |
±0.3% |
±0.3% |
DC output power |
400W |
480W |
480W |
480W |
500W |
Efficiency |
80% |
83% |
84% |
86% |
87% |
Adjustable range for DC voltage |
±10% |
±10% |
±10% |
±10% |
±10% |
AC input voltage range |
100~132VAC/190~240VAC 250~340VDC |
Input current |
5A/230V |
Power factory |
0.65 - 0.75 |
AC Inrush current |
46A/230V |
Leakage current |
< 3.5mA/240VAC |
Overload protection |
105%-150% Type: cut down output. Reset: auto recovery. |
Over-voltage protection |
120%-150% |
High-temperature protection |
ERH3≥ 65°C~70°CFan on, ≤55°C~60°CFan off, ≥80°C~85. Cut off output (5-15V)~(24-48V) |
Temperature coefficient |
±0.03%/°C |
Setup, rise, hold up time |
1s, 100ms, 50ms |
Vibration |
10~500Hz, 2G 10min,/1 cycle. Period for 60min, Each axes |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
Working temperature and humidity |
(-10°C)~+60°C, 10%~95%RH |
Store temperature and humidity |
(-20°C)~+85°C, 10%~95%RH |
Overall dimension |
238X124X65mm (L*W*H) |
Weight |
1.22Kg |
Safety standards |
GB4949, UL60950, EN60950 |
EMC standards |
According to GB9254 EN55022 EN55024 A level design |
Note:
1. The parameter under the testing condition: 230VAC input, rated load, 25°C70% RH. Temperature.
2. Tolerance: Including setting tolerance, circuit stability and load stability. (Note:5).
3. Wave test: Adopting “A12” double wire for 20MHz, and 0.1 UF&47UF capacitor short-circuit for interrupting.
4. Inlet voltage stability test: the lowest voltage will be up to the highest voltage when the circuit overload.
5. Load stability test: The load is from 0% to 100%.
6. C3, 4 must be knocked down.
|