UPS charging power supply Features:

(the user instruction):

RED LED: AC INPUT

GREEN LED: DC OUTPUT

YELLOW LED: battery charge

Long-term floating on the battery charge, high efficiency, battery fullness can reach more than 90%

Which power to the battery charge, no requirements for the type of battery, lead, lithium and other batteries are OK!

Specification:

Model

SC-180-12

SC-180-24



 

output

DC voltage

CH1:12V

CH2:13.8V

CH1: 24V

CH2:27.6V

Voltage tolerance

±2%

-----

±1%

-----

Rated current

13.5A

1.5A

6.5A

1A

Current range

0~15A

-----

0~7.5A

-----

Rated power

182.7W

182.7W

Ripple&noise

120mvp-p

-----

180mvp-p

-----

DCvoltage ADJ.range

CH1:10.3~13.8V

CH1:21.3~27.5V


 

input

Voltage range

90~132VAC/ 180VAC~264VAC Select by switch ,237~370VDC

frequency

47~63HZ

AC current

4A/115VAC,2.5A/230VAC

efficiency

81%

83%

Inrush current

Cold start current  30A/115VAC,50A/230VAC

Leakage current

< 1mA/240VAC

 

protection

Over load

Rated output power110%~150%  start over load protection

protection mode: AC charging mode:hiccup mode auto-recovery after fault condition is removed

Battery protection

At low voltage

9.5~11V

20~22V

protection mode:cutoff output

Function

UPS introduction

long-term online floating charge to battery,high charging efficiency,battery can saturate to more than 90% ,cauto-stop charging when it's full,prevent over charging. Effectively extend battery life,AC/battery auto switch,no switch time,no need human guard,

cold-start ,when there is no AC input ,can use battery start UPS,Meet the user's emergency needs

 

 

 

safety

Withstand voltage

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolated resistance

I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC

Fitstandard

Safety standard

Compliance to UL60950-1

EMC standard

Compliance to EN55022,CLASSB

others

Dimension

199*98*38mm (L*W*H)

Weight/packing

0.6kg/45pcs/26kg/0.041m⊃3;/1.45CUFT




 