MODEL
|
D-30A
|
D-30B
|
OUTPUT
|
DC VOLTAGE
|
5V 12V
|
5V 24V
|
RATED CURRENT
|
4A 1A
|
2.2A 1A
|
CURRENT RANGE
|
0.5 ~ 4A 0.1 ~ 1A
|
0.5 ~ 4A 0.1 ~ 1A
|
RATED POWER
|
32W
|
35W
|
RIPPLE & NOISE (max.) Note.2
|
50mVp-p 100mVp-p
|
50mVp-p 100mVp-p
|
VOLTAGE ADJ. RANGE
|
CH1 : 4.75 ~ 5.5V
|
CH1 : 4.75 ~ 5.5V
|
VOLTAGE TOLERANCE Note.3
|
±2.0% + 3,-7%
|
±2% + 3,-5%
|
LINE REGULATION
|
±0.5% ±1.0%
|
±0.5% ±1.0%
|
LOAD REGULATION
|
+0.5% +4.0%
|
±0.5% ±4.0%
|
SETUP, RISE, HOLD TIME
|
200ms, 50ms, 30ms at full load
|
INPUT
|
VOLTAGE RANGE
|
85 ~ 132VAC / 170 ~ 264VAC selected by switch 240 ~ 370VDC
|
FREQUENCY RANGE
|
47 ~63Hz
|
EFFICIENCY(Typ.)
|
72% 74%
|
AC CURRENT
|
0.8A/115VAC 0.45A/230VAC
|
INRUSH CURRENT(max.)
|
COLD START 18A/115VAC 36A/230VAC
|
LEAKAGE CURRENT
|
<1mA/ 240VAC
|
PROTECTION
|
OVER LOAD
|
105 ~ 150% rated output power
|
Protection type : Fold back current limiting, recovers automatically after fault condition is removed.
|
ENVIRONMENT
|
WORKING TEMP.
|
-10 ~ +60°C (Refer to output load derating curve)
|
WORKING HUMIDITY
|
20 ~ 90% RH non-condensing
|
STORAGE TEMP., HUMIDITY
|
-20 ~ +85°C, 10 ~ 95% RH
|
TEMP. COEFFICIENT
|
+0.03%/°C (0 ~ 50°C)
|
VIBRATION
|
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
SAFETY &
EMC
|
SAFETY STANDARDS
|
Design refer to UL1012
|
WITHSTAND VOLTAGE
|
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATION RESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
|
EMI CONDUCTION & RADIATION
|
Design refer to FCC Part15 J Conduction
|
OTHERS
|
MTBF
|
417.6K hrs min. MIL-HDBK-217F (25°C)
|
DIMENSION
|
129*98*38mm (L*W*H)
|
PACKING
|
0.41 Kg; 30pcs/13.4Kg/0.86CUFT
|
NOTE
|
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
|