Model
Specification
|
S-1200-12
|
S-1200-13.5
|
S-1200-15
|
S-1200-24
|
S-1200-27
|
S-1200-48
|
DC Output voltage(V)
|
12
|
13.5
|
15
|
24
|
27
|
48
|
Output voltage range
|
±1%
|
±1%
|
±1%
|
±1%
|
±1%
|
±1%
|
Rated output current(A)
|
100
|
88.8
|
80
|
50
|
44.4
|
25
|
Output current range(A)
|
0~100
|
0~88.8
|
0~80
|
0~50
|
0~44.4
|
0~25
|
Wave and noise(mVp-p)
|
200
|
200
|
200
|
200
|
200
|
200
|
Inlet stability(%)
|
±0.5
|
±0.5
|
±0.5
|
±0.5
|
±0.5
|
±0.5
|
Load stability(%)
|
±0.5
|
±0.5
|
±0.5
|
±0.5
|
±0.5
|
±0.5
|
DC output power(W)
|
1200
|
1200
|
1200
|
1200
|
1200
|
1200
|
Efficiency(%)
|
84
|
84
|
85
|
85.5
|
86.5
|
87
|
Adjustable range for DC voltage
|
10~13.2V
|
12~15V
|
13.5~18V
|
20~26.4V
|
24~30V
|
41~56V
|
AC input voltage range
|
90~130VAC/190~240VAC 47~63Hz
|
Input current
|
7A/230V
|
AC Inrush current
|
50A/230V
|
Leakage current
|
<3.5mA/240VAC
|
Overload protection
|
105%-150% Type:pulsing hiccup shutdown Reset:auto recovery
|
Over-voltage protection
|
13.8~16.2v
|
15.5~18.2v
|
18~21v
|
27.6~32.4v
|
31~36.5v
|
57.6~67.2v
|
High-temperature protection
|
≥70°C Cut off output(0~50°C)
|
Temperature coefficient
|
±0.03%/°C(0~50°C)
|
Setup, rise, hold up time
|
1.5s, 50ms, 20ms
|
Vibration
|
10~500Hz, 2G 10min,/1 cycle. Period for 60min,Each axes
|
Withstand voltage
|
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
Isolation resistance
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
|
Working temperature and humidity
|
-10°C~+60°C,10%~95%RH
|
Store temperature and humidity
|
-20°C~+85°C,10%~95%RH
|