Power Supply PS-45 5V 12V 15V 24V 48V Wide Range PCB Power Supply
|
Specification | Model | |||
PS-45W-5V | PS-45W-12V | PS-45W-15V | PS-45W-24V | |
DC output | 5V 8A | 12V 3.7 A | 15V 3A | 24V 1.9A |
Wave and noise | 100mVP-P | 100mVP-P | 100mVP-P | 150mVP-P |
Inlet stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability | ±1% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 74% | 76% | 77% | 78% |
VOLTAGETOLERANCE | ±3.0% | ±2.0% | ±2.0% | ±2.0% |
LINEREGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
AC input voltage range | 85 ~ 264VAC 120 ~ 370VDC | |||
AC CURRENT (Typ.) | 0.4A/115VAC 0.2A/230VAC | |||
INRUSH CURRENT (Typ.) | COLD START 40A/230VAC | |||
LEAKAGE CURRENT | <0.5mA / 240VAC | |||
OverLoad protection | 105%~150%hiccup mode ,auto-recovery | |||
Setup,rise,hold up time |
800ms, 30ms at full load |
|||
FREQUENCY RANGE | 47 ~ 440Hz | |||
Withstand voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||
Working temperature | --10 ~ +60°C (Refer to output load derating curve) | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
Safety standards | Design refer to GB4943,UL60950,EN60950 | |||
EMC standards | Design refer to GB9254,EN55022 classA | |||
DIMENSION | 127*76*28mm (L*W*H) | |||
PACKING | 0.19Kg; 72pcs/15.6Kg/1.35CUFT | |||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |