mini type mini size MS series electric industry switching power supply MS series MS-50W
Features:
Had 170 ~ 264 VAC input voltage range
Had small volume, light weight, high efficiency
Characteristics: short circuit protection miscalculates/overload
Had natural cooling
With that took on light emitting diode (led)
1 0, 0% had burned machine full load test
Model |
|
MS-50-5 |
MS-50-12 |
MS-50-15 |
MS-50-24 |
Output |
DC output Voltage |
5V |
12V |
15V |
24V |
Voltage tolerance |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Rated Current |
10A |
4.2A |
3.4A |
2.1A |
Related Power |
50w |
50w |
50w |
50w |
Wave&Noise |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Adjustable range for DC Voltage |
±10% |
±10% |
±10% |
±10% |
Set up,rise,hold up time |
200ms 100ms 30ms |
Input |
Voltage Range |
85 ~132VAC 170-264VAC 47-63HZ 240-370VDC |
Input Current |
1.2A/115VAC 0.6A/230VAC |
Efficiency |
71% |
78% |
78% |
82% |
AC inrush current |
Cold start current 15A/115V 30A /230VAC |
Leakage current |
<0.5mA/240VAC |
Protection |
Overload |
Related output power 105-150% start overload protection |
Protection type: cutoff output, recovery after restart power |
Over voltage |
5.75V-6.75V |
13.8V-16.2V |
17.2V-20.2V |
27.6V-32.4V |
Hiccup mode,recovers automatically after fault condition |
Environment |
Working temp humidity |
-10~+60°C 20%~90%RH |
Stor temp, humidity |
-20~+85°C 20%~90%RH Non-condensing |
Safety |
Withstand voltage |
I/P-O/P:1.5KVAC 1min |
I/P-FG:1.5KVAC 1min |
O/P-FG:0.5KVAC 1min |
Standard |
Safety standard |
Fit UL1012 |
Refer |
Design refer to GB4943,UL60950,EN60950 |
EMC standard |
Design refer to GB9254,EN55022 Class A |
Size |
size |
L111*W78*H36mm |
Package |
0.27kg, 70pcs/20kg |
|