(Model)
(Specification)
|
MS-35-5
|
MS-35-12
|
MS-35-15
|
MS-35-24
|
DC output voltage
|
5V
|
12V
|
15V
|
24V
|
Output voltage range
|
±2%
|
±1%
|
±1%
|
±1%
|
Rated output current
|
7A
|
3A
|
2.4A
|
1.45A
|
Output current ranqe
|
0-7A
|
0-3A
|
0-2.4A
|
0-1.45A
|
Wave and noise
|
75mVp-p
|
75mVp-p
|
75mVp-p
|
50mVp-p
|
Inlet stability
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Load stability
|
±1%
|
±0.5%
|
±0.5%
|
±0.5%
|
DC output power
|
35W
|
36W
|
36W
|
35W
|
Efficiency
|
70%
|
76%
|
78%
|
80%
|
Adjustable range for DC voltage
|
±10%
|
±10%
|
±10%
|
±10%
|
AC input voltage range
|
170-264VAC 47-63Hz,240-370VDC
|
Input current
|
0.45A/230V
|
AC Inrush current
|
Cold-start current 36A/230V
|
Leakage current
|
<0.5mA/240VAC
|
Overload protection
|
105%-150% Type: pulsing hiccup shutdown Reset: auto recovery
|
Over-voltage protection
|
…………
|
High-temperature protection
|
…………
|
Temperature coefficient
|
±0.03%/°C(0~50°C)
|
Setup, rise, hold up time
|
200ms,100ms,30ms
|
Vibration
|
10~500Hz, 2G 10min,/1 cycle. Pariod for 60min,Each axes
|
Withstand voltage
|
Input and output internal:1.5KvAC,Input and enclosure:l.5KvAC,Output and enclosure:0.5KvA
|
Isolation resistance
|
input and output internal Input and enclosure ,Output and enclosure:500VDC/100MΩ
|
Working temperature and humidity
|
-10°C~+60°C,20%~90%RH
|
Store temperature and humidity
|
-20°C~+85°C,10%~95%RH
|
Overall dimension
|
85X58X38mm
|
Weight
|
0.4kgS
|
Safety standards
|
Meet UL 1012 requirement(Not apply for the mark)
|
EMC standards
|
Meet FCC PART15 J Conduction class B
|