50W Three sets
Model Number |
Output |
Tol |
RCN |
Effi |
PP |
T-50A |
5V,0.6~7.0A |
± 2% |
100mV |
66% |
52W |
12V.0.2-1.0A |
土 5% |
100mV |
-5V,0.2~1.0A |
土 5% |
100mV |
T-50B |
5V,0.6~5.0A |
± 2% |
150mV |
69% |
49W |
12V.0.2-1.0A |
土 5% |
100mV |
-12V.0.1〜1.0A |
土 5% |
150mV |
T-50C |
5V,0.6~4.0A |
± 2% |
100mV |
71% |
50W |
15V.0.2-1.0A |
土 5% |
100mV |
-15V.0.2〜1.0A |
土 5% |
100mV |
T-50D |
5V,0.6~4.0A |
± 2% |
50mV |
72% |
51W |
12V.0.2-1.8A |
± 6% |
120mV |
24V,0.2~1A |
± 6% |
120mV |
AC input range selectable by switch
•Protections:Short circuit/Over load
•Cooling by free air convection
• 100% full load burn-in test
•Low cost.high reliability
• 2 year warranty
• AC input voltage range: 85-132VAC/170264VAC 47~63Hz ;selectabe by switch
• AC inrush current: Cold start.15A at 115VAC.30A at 230VAC
•Dcadjustment range: ± 10% rated output voltage
• Over load protection: 105%~150% fold back current limiting.auto-recovery
•Setup.rise.hold up time: 200ms.50ms.16ms at full load and 230VAC
•Withstand voltage: l/P-O/P:1.5KVAC.l/P-FG:0.5KVAC.1minute
• Working temperature: -10^~ + 60^, 20%~90%RH
• Safety standards: Design refer to UI1012
EMC standards : Design refer to FCC part 15
• Connection: 5P/9.5mm pitch terminal block
• Packing: 0.54kg;30pcs/17.2kg/1.0CUFT